Amprobe AC68C True-rms 600A Clamp Meter measures non-linear load current with true-rms readings.
Features
- 8 functions/11 ranges
- Data and AC peak hold
- DC auto zero
- Carrying case included
- 33⁄4 digit, LCD, max reading of 3999
- 9 V battery
- Maximum jaw opening: 40 mm (1.57˝)
- Autoranging for frequency measurement;
- Low battery indication
- Auto-power off after 30 minutes
- Included accessories: test leads, battery, manual and carrying case
- Manual function and range selection with rotary selector
Specifications
FEATURE | AC68C |
True-rms | • |
AC Voltage | 600 V |
DC Voltage | 400.00 V, 600 V |
AC Current | 400.00 A, 600 A |
DC Current | 400.00 A, 600 A |
Micro Amps | – |
Resistance | 4.000 kO |
Continuity | • |
Capacitance | – |
Frequency | 4 kHz, 20 kHz |
Temperature | – |
Accommodates conductors | up to 1.3 (35 mm) in diameter |
Specifications | |
DC Voltage ranges: | 600 V |
DC Voltage accuracy: | ± (0.75 % rdg + 2 dgts) |
DC Voltage resolution: | 1 V in 600 V range |
DC Voltage input impedance: | 10 MO |
AC Voltage (40-450 Hz) range: | 400 V, 600 V |
AC Voltage (40-450 Hz) accuracy: | ± (1.2 % rdg + 5 dgts) |
AC Voltage (40-450 Hz) resolution: | 0.1 V in 400 V range |
AC Voltage (40-450 Hz) input impedance: | 10 MO |
DC Current ranges: | 400 A, 600 A |
DC Current accuracy: | ± (2 % rdg + 5 dgts) |
DC Current resolution: | 0.1 A in 400 A range |
AC Current (40-450 Hz): | 400 A, 600 A |
AC Current (40-450 Hz): | ± (2 % rdg + 5 dgts) |
AC Current (40-450 Hz): | 0.1 A in 400 A range |
Frequency (Hz), current and voltage ranges: | 4 kHz, 20 kHz |
Frequency (Hz), current and voltage accuracy: | ± (0.5 % rdg + 5 dgts) |
Frequency (Hz), current and voltage resolution: | 1 Hz in 4 kHz range |
Frequency (Hz), current and voltage sensitivity: | 5 A/1 V in 4 kHz range, 5 A/5 V in 20 kHz range |