(item no. 3730013)
The Amprobe ACD-45PQ is a compact digital clamp meter capable of measuring power, energy and power factor on a single and three-phase systems (balanced and unbalanced). Ultra-slim jaw design allows the user to clamp around conductors in confined and difficult to reach places. This digital clamp meter is also true-rms sensing takes reliable AC/DC voltages measurements up to 600V.
Features
- True-rms sensing
- Ultra slim jaws accommodate conductors up to 1.02 (26mm) in diameter
- Measurements: AC/DC Vvoltage up to 600V, AC current up to 600A, resistance, frequency power: active (W), reactive (VAR) and apparent (VA) power with dual-display power factor readout, KWh recording
- AutoVA – auto selection of AC volts, DC volts or AC amps
- 3 phase unbalanced load measurement – calculation of the discrete single phase measurements
- Optional PC interface capability (RS-232 KIT2)
- Audible continuity
- Large, easy to read LCD display with backlight
- Auto power off
- Low battery indication
- Peak hold
- Data hold
- Carrying case, test leads, batteries (installed), and manual included
- Voltage overload protection for all functions up to 600V AC/DC
Specifications
FEATURE | ACD-41PQ | ACD-45PQ |
True-rms | • | |
AC Current | 40.00 A, 400.0 A, 1000 A | 40.00 A, 400.0 A, 600 A |
AC/DC Voltage | 600.0 V | |
Resistance | 999.9 Ω | |
Continuity | • | |
Temperature | -58 °F → 572 °F (-50 °C → 300 °C) | – |
Frequency | 5.00 Hz → 500.0 Hz | |
Active power | (W) 0 kW → 600.0 kW | 0 kW → 360.0 kW |
Reactive power (VAR) | 0 kVAR → 600.0 kVAR | 0 kVAR → 360.0 kVAR |
Apparent power (VA) | 0 kVA → 600.0 kVA | 0 kVA → 360.0 kVA |
Power factor | 0.10 → 0.99 | |
Energy (KWHr) | – | • |
Total harmonic distortion (THD%) | 0.0 % → 99 % | – |
Accommodates conductors | up to 1.77″ (45 mm) in diameter | up to 1.02″ (26 mm) in diameter |
Specifications | |
Display: | Voltage functions: 6000 counts LCD display Power Ohm & Hz functions: 9999 counts LCD display AC A clamp-on function: 4000 counts LCD display |
Update rate: | Power function: 2 per second nominal Voltage, AC A clamp-on & Ohm functions: 2 per second nominal Hz function: 1 per second nominal |
Polarity: | Automatic |
Sensing: | True-rms sensing |
Safety: | Meets IEC61010-1 2nd Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed. CAN/CSA C22.2 No.61010.1-0.92, IEC61010-2-032, EN61010-2-032 & UL61010B-2-032, |