(item no. 4629301)
Product Overview
All the facts, right in the field. The Fluke a3004 FC Wireless 4-20 mA Current Clamp Meter is one member of a family of wireless test tools that let you record and log data over time and share test data using the Fluke Connect® app with ShareLive™ video call.
Fluke Connect Wireless Test Tools put tools where measurement access or separation may be an issue. It’s simple. Connect the a3004 FC current meter, or any of the other Fluke Connect remote meters, and read the results on the Fluke Connect Wireless Multimeter or a PC from a safe distance.
Better still, the Fluke Connect test tools can send measurement data to your smartphone, so you can save and share measurements from the field with your team anytime, from anywhere.
Test or troubleshoot 4-20mA control loops used with drive systems, plc’s, or building energy management systems.
Features
Fluke a3004 FC Wireless 4-20mA DC Clamp Meter is a fully functional current clamp meter that wirelessly relays measurements to other Fluke Connect® enabled master units, listed below:
- Fluke 3000 FC DMM
- Fluke Ti200/300/400 Infrared Camera
- PC via optional pc3000 FC Adapter
- Fluke Connect Mobile app
- TiX560 and TiX520
Fluke a3004 FC Wireless 4-20 mA DC Clamp Meter main features include:
- Measure 4 to 20 mA signals without “breaking the loop”
- Detachable clamp with extension cable for measurements in tight locations
- Use as a standalone meter or as part of the system
- Use the logging function for the recording and saving up to 65,000 measurements
Specifications: Fluke a3004 FC Wireless 4-20 mA DC Clamp Meter
DC Current Function | |
Range | 0.05 mA to 20.99 mA DC 21.0 mA to 99.9 mA DC |
Resolution | 0.01 mA 0.1 mA |
Accuracy | 0.2% ± 5 digits 1.0% ± 5 digits |
Specifications | |
LCD w/backlight | 3 ½ digits |
Log rate/Interval | 1 sec minimum/adjustable by PC or front pannel |
Battery type | 2 AA NEDA 15 A IEC LR6 |
Battery life | 45 hours |
Memory | Record up to 65,000 readings |
RF communications | 2.4 GHz ISM Band |
RF communication range | Open air, unobstructed: Up to 20 m Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m |
Operating temperature | -10°C to +50°C |
Storage temperature | -40°C to +60°C |
Temperature coefficient | Add 0.1 X (specified accuracy) /°C (< 18°C or > 28°C) |
Operative humidity | 90% at 35°C 75% at 40°C 45% at 50°C |
Altitude | Operating 2,000 m Storage 12,000 m |
EMC | EN 61326-1:2013 |
Maximum voltage between terminal and earth ground (module) | 30 V DC or AC rms |
Certifications | CSA C-US CE FCC: T68-FBLE IC: 6627A-FBLE |
Ingress Protection (IP) rating | IP42 |
Jaw opening | 4.5 mm |
Size (HxWxD) | 16.5 mm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) |
Weight | 0.299 kg (0.8 lb) |
Note: Not compatible with Fluke CNX test tools. |
Includes:
- a3004 meter module
- Batteries
- Hanging strap
- Quick start guide
Manuals
- a3003 FC and a3004 FC | Statement of memory volatility
- a3003 FC/a3004 FC | Calibration manual
- a3004 FC | Quick reference guide
- a3004 FC | Safety sheet
- a3004 FC | Safety sheet supplement