- Displays cable length, wiremap, cable ID, and distance to fault on one screen
- Detects today’s media services, including 10/100/1000 Ethernet, POTS, and PoE
- Locates virtually any cable or wire pair with IntelliTone digital and analog toning
- Tests all common media types, including RJ11, RJ45, Coax, with no adapters
- Rubber over mold enhances grip and increases ruggedness
- “Oversized” backlit LCD makes results crystal clear in any work environment
- Magnetic Strap attachment allows technicians to keep their hand’s free and their tester safe from potential drops and accidents with its strong rare earth magnet
Raising cable verification to a higher power
Rule out service problems fast
Today’s communications technicians have a lot more problems to deal with than just the cabling. They have to rule out a whole host of potential cable and service issues before determining the cause of a connection problem. Is there telephone voltage? What’s the polarity? Is there an Ethernet switch at the far end? Is PoE available? MicroScanner2 acknowledges this, giving technicians high power vision to verify today’s most common voice, data, and video services. That means faster, more comprehensive troubleshooting.
Reduce test time and user error
Yesterday’s cable verification testers force users to toggle between different modes (up to four) to view all test results. This not only slows the test process, but also causes user frustration and error. MicroScanner2 has defied this convention by displaying key test results – wiremap, pair lengths, distance to fault, cable ID, and far-end devices – all on one screen.
Tired of losing or breaking all the adapters needed for testing the various voice, data, and video media types? MicroScanner2 makes these adapters things of the past with builtin RJ11, RJ45, and coax support. Both the main unit and the far-end identifiers can be used to test telephone jacks, Ethernet jacks, and CATV outlets right out of the box.
Rule out service problems fast
Today’s communications technicians have more problems to deal with than just the cabling. They have to rule out a whole host of cable and service issues before determining the cause of a connectivity problem. Is there telephone voltage? What’s the polarity? Is there a switch at the far end? Is PoE available? MicroScanner2 gives technicians high power vision to verify today’s most common voice, data, and video services.
Locate elusive cables in seconds
MicroScanner2 features built-in IntelliTone digital and analog toning to precisely locate virtually any cable or wire pair, regardless of work environment. Use digital mode to locate high-grade data cabling (Cat 5e/6/6a) in bundles, or at switches, patch panels, or wall outlets. Or, use analog mode on voice-grade cabling (Cat 3 and below), as well as coax, security/alarm, and speaker wiring.
Repair or replace tools less often
With all the abuse you put your tools through, you can’t afford for them to be delicate. MicroScanner2 features a rubber wrap-around holster that makes it the right tool for even the toughest jobs. Toss it into your toolbox. Drop it from a ladder. It can handle it. Plus, it now comes standard with a vinyl carry pouch for enhanced protection and convenience.
High power vision into voice/data/video cabling
For more than a decade, cabling installation and maintenance technicians have relied on MicroScanner to verify terminations and troubleshoot continuity faults. A lot has changed in the cabling world since the original MicroScanner was introduced. Industry economics require that installations be done fast and accurately with no callbacks. And converging voice, data, and video technologies have given rise to new requirements for service testing and multimedia support.
MicroScanner2 recognizes these trends and presents a much-needed revolution to the way testing is done. It streamlines every aspect of the verification job. From its time-saving user interface and integrated multimedia support to its expanded service detection capabilities, MicroScanner2 gives technicians the power to perform their jobs faster and more accurately than ever.
High power vision to verify voice/data/ video cabling and services. That’s Network SuperVision.™ That’s Fluke Networks’ promise to you.
MicroScanner2 Cable Verifier Features
Pro 3000 | Intellitone Pro | MicroMapper | TS100 PRO | MS2-100 | CIQ-100 | |
Port Location ID | ||||||
Digital Toning | ✔ | ✔ | ✔ | |||
Analog Toning | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
Switch Presence | ✔ | ✔ | ✔ | |||
VDV Service Detection | ✔ | ✔ | ||||
Cable Verification | ||||||
Cable Wiremap | ✔ | ✔ | Graphical | Graphical | ||
Cable Length | ✔ | ✔ | ✔ | |||
Qualified Cabling Speed (10/100/1000/VoIP) | ✔ | |||||
Cable Troubleshooting | ||||||
Indentify open/short | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
Distance to open/short | ✔ | ✔ | ✔ | |||
Locate crosstalk fault | ✔ | |||||
Identify and locate impedance fault | ✔ |
In The Box
MS2-100:
- 2 – AA Alkaline Batteries
- 1 – Carrying Pouch
- 1 – Getting Started Guide
- 1 – Users Manual on CD-ROM
FTK1000:
- SimpliFiber Pro optical power meter
- 850/1300 multimode source
- SC power-meter adapter
- Carrying Case
Manufacturer Specs
MS2-100 Specifications | |||
Test Connectors | Twisted-pair: UTP, FTP, SSTP 8-pin modular jack accepts 8-pin modular (RJ45) and 4-pin modular (RJ11) plugs Coax: F-connector for 75 O, 50 O, 93 O cables |
||
Cable Tests | Length (460 m or 1500 ft. with resolution to 0.3 m or 1 ft.), wiremap to TIA-568A/B standards, remote ID locators; displays results on one screen | ||
Tone Generator | IntelliTone digital tone: [500 KHz]; analog tones: [400Hz, 1KHz] | ||
PoE Detection | Solicits and detects the presence of 802.3af compatible PoE (Power over Ethernet) devices | ||
Ethernet Port Test | Advertised speed of 802.3 Ethernet ports (10/100/1000) | ||
Power Source | Battery type: 2 AA (NEDA 15A, IEC LR6) alkaline batteries Battery life: 20 hours of typical use Other compatible battery types: 2 AA photo lithium, NIMH, NICAD |
||
Dimensions | 3 in x 6.4” x 1.4 in (7.6 cm x 16.3 cm x 3.6 cm) | ||
Weight | 0.8 lbs. (363 grams) | ||
Display | Monochrome liquid crystal display (LCD) with backlight | ||
Calibration | User-configurable NVP for twisted pair and coax; determines actual NVP with known length of cable | ||
Operating Temperature | 32 °F to 113 °F (0 °C to 45 °C) | ||
Storage Temperature | -4 °F to +140 °F (-20 °C to +60 °C) | ||
Operating Humidity | 90 % (50 °F to 95 °F; 10 °C to 35 °C) | ||
(%RH without condensing) | 75 % (95 °F to 113 °F; 35 °C to 45 °C) | ||
Shock Vibration | Meets requirements for MIL-PRF-28800F for Class 2 random vibration 1 m drop test with and without wiremap adapter attached |
||
Safety | EN 61010-1 2nd Edition | ||
Altitude | 4000 m; Storage: 12000 m | ||
EMC | EN 61326-1 | ||
Agency Certifications | N10140 C-Tick EMC standard; FCC Part 15 Class A; CE European Union Directives Pollution Degree 2 |
||
Warranty | One year | ||
FTK1000 Specifications | |||
Environmental Specifications | |||
Temperature range | Operating: -10º C to 50º C Storage: -20º C to 50º C |
||
Operating Humidity | 95% (10º C to 35º C) Non-Condensing 75% (35º C to 40º C) Non-Condensing Uncontrolled <10º C |
||
EMI, RFI, EMC | Standards compliant1 | ||
Notes | 1 Conforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1) | ||
Optical Power Meter | |||
Detector Type | InGaAs | ||
Calibrated Wavelengths | 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm | ||
Emitter wavelengths | 850/1300 Source: 850 nm and 1300 nm 1310 Source: 1310 nm 1550 Source: 1550 nm |
||
Measurement Range | +10 to -52 dBm (850 nm) +10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm) |
||
Power Measurement Linearity | ±0.2 dB (850 nm)1 ±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)2 |
||
Power Measurement Uncertainty3 | ±0.25 dB | ||
Display Resolution, dB or dBm | 0.01 dB | ||
Auto Dual-Wavelength Switching | Yes | ||
Power Display Units | dBm, mW, µW | ||
Auto-Wavelength Detection | Yes | ||
Data Storage | 1000 records, multiple wavelengths per record | ||
External Interface | USB, 2.0 full speed | ||
Optical Connector | Removable adapter, SC adapter as default, optional adapters include LC, ST | ||
Display update rate | 1 reading per second | ||
Reference | Individually set for each wavelength | ||
FindFiber ID detection | Yes | ||
Power Requirement | 2 AA Alkaline batteries | ||
Battery Life4 | > 50 Hours (typical) | ||
Automatic Power Off | 10, 20, 30 or 60 minutes (can be disabled by user) | ||
Low Battery Warning | Yes, low battery icon blinks | ||
Size (L x W x H) | 6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm) | ||
Weight | 11.5 oz (325 grams) | ||
Notes |
1 For 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power < -45 dBm 2 ±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power > 0 dBm and < -55 dBm 3 23°C ±2°C, power level -20dBm, continuous wave, 62.5/125µm at multi mode wavelengths, 9/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm 4 For measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries. |
||
Multimode Optical Source | |||
Emitter Type | LED | ||
Central Wavelength | 850 nm, 1300 nm | ||
Wavelength Accuracy | 850 nm: +30/- 10 nm 1300 nm: ± 20 nm |
||
Spectral Width (FWHM) | 850 nm: 50 nm (typical) 1300 nm: 135 nm (typical) |
||
Minimum Output Power | 850/1300 nm: ³ -20 dBm | ||
Power Output Stability1 | ±0.1 dB over 8 hours | ||
Auto Dual-Wavelength Switching | Yes. Can be enabled/disabled by user. | ||
Optical Output Connector | Fixed SC | ||
FindFiber Code Generation | Yes. Fixed at ID 1. | ||
Modes | CW, 2 kHz modulated, Auto-wavelength | ||
Power Requirement | 2 AA Alkaline batteries. | ||
Battery Life2 | 40 hrs (typical) | ||
Automatic Power Off | 30 minutes (can be disabled by user) | ||
Low Battery Warning | Yes, LED blinks | ||
Size (L x W x H) | 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm) | ||
Weight | 1.8 oz (278 g) | ||
Notes |
1 23° C ± 2° C, after 5 minutes warm-up time 2 In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries. |